{"id":157,"date":"2026-04-14T21:18:49","date_gmt":"2026-04-14T21:18:49","guid":{"rendered":"https:\/\/www.imbrr.com\/blog\/?p=157"},"modified":"2026-04-15T07:14:47","modified_gmt":"2026-04-15T07:14:47","slug":"how-to-detect-an-improperly-sized-well-pump","status":"publish","type":"post","link":"https:\/\/www.imbrr.com\/blog\/how-to-detect-an-improperly-sized-well-pump\/","title":{"rendered":"How to Detect an Improperly Sized Well Pump"},"content":{"rendered":"\n<p>Well pumps rarely have instantaneous failures. Normally, small problems build up over months or even years before the system has a noticeable malfunction.&nbsp; Due to detection difficulty, improperly sized well pumps have historically been one of those unnoticeable problems that can significantly reduce the pump life.&nbsp;<\/p>\n\n\n\n<p>This doesn\u2019t have to be the case with a <a href=\"https:\/\/www.imbrr.com\/\">real time well monitoring system<\/a>.&nbsp; Now, changing pump performance can instantly be spotted and addressed to maintain system longevity.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Can This Happen in the First Place?<\/h2>\n\n\n\n<p>Well, let\u2019s review how pumps are sized.&nbsp; In general, pumps are selected to meet two requirements: the maximum household flow rate and total lift.&nbsp;<\/p>\n\n\n\n<p>The maximum flow rate is a function of household fixtures, bathrooms, and irrigation requirements and is measured in gallons per minute (GPM). &nbsp;The lift, measured in feet (ft), is referred to as the Total Dynamic Head (TDH) and is a function of well performance and location.&nbsp; Specifically, it is calculated with this simplified equation:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">TDH = Pumping Level + Elevation Gain (Well to House) + Household Pressure + Pipe Friction<\/h4>\n\n\n\n<p>The important observation is that elevation gain almost always remains constant.&nbsp; However, the water demand, pumping level, pressure, and pipe friction can vary dramatically over time.&nbsp; Without continuous monitoring, well pumps are frequently sized on a limited set of test data and assumptions.&nbsp; Any changes can cause a once properly sized pump to be undersized or oversized.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pump Selection<\/h2>\n\n\n\n<p>After the flow rate and TDH requirements are determined, a pump\u2019s performance curve is typically leveraged to confirm fit.&nbsp; An example is shown below:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"589\" src=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image.png\" alt=\"Graph showing a standard pump curve.  As the flow increases, the lift decreases.\" class=\"wp-image-159\" srcset=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image.png 975w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-300x181.png 300w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-768x464.png 768w\" sizes=\"auto, (max-width: 975px) 100vw, 975px\" \/><\/figure>\n\n\n\n<p>For the purposes of this article, you only need to know that the pump will produce the maximum lift at the lowest flow rate and the lowest lift at the highest flow rate.&nbsp; The exact operating point is always changing as the water demand and TDH fluctuate.&nbsp;<\/p>\n\n\n\n<p>Ideally, the pump should operate in the middle of the pump curve for maximum efficiency.&nbsp; However, an undersized pump will operate with low flow to maximize the lift while an oversized pump will produce high flow well beyond the pump rating.&nbsp; This can be visualized in the graph below:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"608\" src=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-1.png\" alt=\"Improperly sized pump regions are overlaid on a pump curve.  Undersized pump conditions are in the low flow region.  Oversized pump conditions are in the high flow region.  Properly sized conditions are in the middle of the curve.  \" class=\"wp-image-160\" srcset=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-1.png 975w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-1-300x187.png 300w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-1-768x479.png 768w\" sizes=\"auto, (max-width: 975px) 100vw, 975px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Detecting Pump Sizing Issues<\/h2>\n\n\n\n<p>Since the operating point is always changing, the <a href=\"https:\/\/www.imbrr.com\/\">imbrr Well Monitoring System<\/a> offers a convenient way to track potential performance concerns.&nbsp; Let\u2019s take a look at a case study of an undersized well pump:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"364\" src=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-2.png\" alt=\"Example from the imbrr dashboard showing low flow rates (almost zero) and long runtimes (almost one hour).  This would indicate an undersized pump.\" class=\"wp-image-161\" srcset=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-2.png 975w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-2-300x112.png 300w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-2-768x287.png 768w\" sizes=\"auto, (max-width: 975px) 100vw, 975px\" \/><\/figure>\n\n\n\n<p>This pump was initially sized to run at ~7 GPM, charging the pressure tank in approximately 2-3 minutes.&nbsp; However, due to the water level dropping 200 ft over time, it\u2019s now running at 0.3 GPM and taking almost an hour to satisfy the pressure switch!&nbsp; This is at extreme risk of deadheading the pump which would likely destroy internal seals, damage the impellor, and melt PVC components\/piping from rapid heat buildup.&nbsp; This is an expensive repair.&nbsp;<\/p>\n\n\n\n<p>Fortunately, a minimum flow rate alert can be set to proactively detect this dangerous condition (1 GPM is a common threshold to alert of a problem):<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"669\" height=\"394\" src=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-3.png\" alt=\"Example setting a low flow alert in the imbrr dashboard to detect an undersized pump.\" class=\"wp-image-162\" srcset=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-3.png 669w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-3-300x177.png 300w\" sizes=\"auto, (max-width: 669px) 100vw, 669px\" \/><\/figure>\n\n\n\n<p>Conversely, an oversized well pump will operate with high flow rate and low runtimes.&nbsp; While it may seem prudent to upsize your pump, oversized well pumps are prone to short cycling, over pumping the well, piping pressure surges, and higher energy costs.&nbsp; This almost always leads to a pump that doesn\u2019t last as long, costs more to run, and can prematurely damage the piping system and\/or well.&nbsp; An ON time of less than 1min is a good indication of a potential oversized pump:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"350\" src=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-4.png\" alt=\"Example from the imbrr dashboard showing high flow rates and short runtimes.  This would indicate an oversized pump.\" class=\"wp-image-163\" srcset=\"https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-4.png 975w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-4-300x108.png 300w, https:\/\/www.imbrr.com\/blog\/wp-content\/uploads\/2026\/04\/image-4-768x276.png 768w\" sizes=\"auto, (max-width: 975px) 100vw, 975px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Remediation Techniques<\/h2>\n\n\n\n<p>While the obvious fix is to correct the pump size, this is an expensive procedure if the pump is still working properly.&nbsp; As such, a list of lower cost techniques can be found below which are often suitable alternatives:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Undersized Pumps<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Maximize well levels and production \u2013 see this <a href=\"https:\/\/www.imbrr.com\/blog\/how-to-maximize-well-production-and-longevity\/\">blog<\/a>.<\/li>\n\n\n\n<li>Lower household pressure \u2013 see this <a href=\"https:\/\/www.imbrr.com\/blog\/how-to-adjust-and-monitor-a-pressure-tank\/\">blog<\/a> on adjusting the pressure switch.<\/li>\n\n\n\n<li>Pump into a cistern rather than pressure tank.&nbsp; This will eliminate the discharge pressure thereby lowering the lift requirement.<\/li>\n<\/ol>\n\n\n\n<h4 class=\"wp-block-heading\">Oversized Pumps<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Upsize the pressure tank to reduce short cycling and extend the runtime.<\/li>\n\n\n\n<li>Adjust pressure switch for a wider differential \u2013 see this <a href=\"https:\/\/www.imbrr.com\/blog\/how-to-adjust-and-monitor-a-pressure-tank\/\" data-type=\"link\" data-id=\"https:\/\/www.imbrr.com\/blog\/how-to-adjust-and-monitor-a-pressure-tank\/\">blog<\/a>.<\/li>\n\n\n\n<li>Install a VFD controller which will allow you to tune the pump speed.<\/li>\n<\/ol>\n\n\n\n<p>Hopefully this discussion helps identify potential pump sizing problems while offering some unique ways to address.&nbsp; The <a href=\"https:\/\/www.imbrr.com\/\">imbrr Well Monitoring System<\/a> makes it easy to spot these conditions, allowing for proactive correction before expensive repairs are needed.<\/p>\n\n\n\n<p>Have feedback on this article or want to discuss your individual results?&nbsp; Please reach out to us at <a href=\"mailto:support@imbrr.com\">support@imbrr.com<\/a>.&nbsp; We are happy to provide additional suggestions to solve your unique problem statements.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Improperly sized pumps play a key role in the longevity of a well system.  This article shows how to detect and proactively correct these conditions to avoid costly pump repairs.<\/p>\n","protected":false},"author":2,"featured_media":158,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[20,18,17,19,5],"class_list":["post-157","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-well-system-problems","tag-oversized-pump","tag-pump-performance","tag-pump-sizing","tag-undersized-pump","tag-well-monitoring"],"_links":{"self":[{"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/posts\/157","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/comments?post=157"}],"version-history":[{"count":7,"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/posts\/157\/revisions"}],"predecessor-version":[{"id":171,"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/posts\/157\/revisions\/171"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/media\/158"}],"wp:attachment":[{"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/media?parent=157"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/categories?post=157"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.imbrr.com\/blog\/wp-json\/wp\/v2\/tags?post=157"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}